Sample data from Engineering Database — 375 reference tables, deterministic calculators, and Engineering AI. Sign up free
Home/Reference Data/Hx Fouling Factors/tubular asphalt 450f dowtherm vapor

Hx Fouling Factors: tubular asphalt 450f dowtherm vapor

Heat exchanger fouling factors (fouling resistance) for various fluid services — single-fluid TEMA values plus combined (total dirt) fouling resistance for common shell-and-tube service pairs from Perry's CEH Table 11-3

Mechanical Engineeringservice id: tubular asphalt 450f dowtherm vapor1 row
service idfluid servicefouling factor combined hhf (h·ft2·°F/Btu)fouling factor max m2k w (m2K/W)fouling factor min m2k w (m2K/W)hx typeshell sidestandardtube side
tubular asphalt 450f dowtherm vaporAsphalt 450°F / Dowtherm vapor (condensing)0.0060.0010570.001057shell-and-tubeAsphalt (450°F)Perry's Chemical Engineers' Handbook, 8th Ed., Table 11-3Dowtherm vapor