Hazop Guide Words: MORE

HAZOP guide words and deviations — IEC 61882:2016 guide words applied to common process parameters across node types (pipe, vessel, reactor, heat exchanger, pump, compressor, control loop, batch step), with typical causes, consequences, and safeguards

Chemical Engineeringguide_word: MORE3 rows
guide worddeviation keycontextdeviation descriptionlikelihood classnode typeprocess parameterseverity classtypical causestypical consequencestypical safeguards
MOREflow#control_loop#generalgeneralControl valve fails open — flow higher than setpointpossiblecontrol_loopflowmoderateValve actuator failure; instrument air failure (fail-open valve); controller output saturated high; instrument loop failureOverfilling of controlled vessel; high-flow induced erosion; product loss; environmental releaseHigh-flow alarm; valve position feedback; independent high-level alarm on vessel; fail-safe valve position specification
MOREflow#heat_exchanger#tube_sidetube_sideHeat exchanger tube-side flow rate higher than designpossibleheat_exchangerflowminorUpstream control valve failure; pump overspeed; bypass valve opened; increased upstream pressureIncreased pressure drop; erosion of tube sheet; vibration-induced fatigue; fouling/scale formation on tube ODFlow controller on tube-side inlet; differential pressure indicator; tube velocity calculation during design; inspection schedule
MOREflow#pipe#generalgeneralFlow rate higher than design intentpossiblepipeflowmoderateControl valve failure open; bypass valve inadvertently open; upstream pressure surge; increased line pressure; operator errorOverfilling of vessel; line erosion at high velocity; heat exchanger fouling/damage; flooding of downstream equipmentHigh-flow alarm (FAH); control valve positioner feedback; flow controller with high-limit; relief device on vessel