Sample data from Engineering Database — 375 reference tables, deterministic calculators, and Engineering AI. Sign up free

Effectiveness Ntu: Shell-and-tube 2-pass

0.50 1.0 to 0.75 1.0

Heat exchanger effectiveness (ε) vs. number of transfer units (NTU) and capacity ratio (Cr = Cmin/Cmax) for seven flow configurations: parallel-flow, counterflow, shell-and-tube 1-pass, shell-and-tube 2-pass, crossflow both unmixed, crossflow Cmin mixed, crossflow Cmax mixed. Data digitized from Incropera Figures 11.10-11.15.

Mechanical Engineeringhx configuration: Shell-and-tube 2-pass10 rowsPage 3 of 5
hx configurationskcapacity ratio (dimensionless)effectiveness (dimensionless)ntu (dimensionless)
Shell-and-tube 2-pass0.50 1.00.50.551
Shell-and-tube 2-pass0.50 1.50.50.681.5
Shell-and-tube 2-pass0.50 2.00.50.752
Shell-and-tube 2-pass0.50 2.50.50.812.5
Shell-and-tube 2-pass0.50 3.00.50.853
Shell-and-tube 2-pass0.50 4.00.50.94
Shell-and-tube 2-pass0.50 5.00.50.935
Shell-and-tube 2-pass0.75 0.00.7500
Shell-and-tube 2-pass0.75 0.50.750.340.5
Shell-and-tube 2-pass0.75 1.00.750.511

What else is in Engineering Database

Related data