Sample data from Engineering Database — 375 reference tables, deterministic calculators, and Engineering AI. Sign up free

Effectiveness Ntu: Shell-and-tube 2-pass

0.25 0.5 to 0.50 0.5

Heat exchanger effectiveness (ε) vs. number of transfer units (NTU) and capacity ratio (Cr = Cmin/Cmax) for seven flow configurations: parallel-flow, counterflow, shell-and-tube 1-pass, shell-and-tube 2-pass, crossflow both unmixed, crossflow Cmin mixed, crossflow Cmax mixed. Data digitized from Incropera Figures 11.10-11.15.

Mechanical Engineeringhx configuration: Shell-and-tube 2-pass10 rowsPage 2 of 5
hx configurationskcapacity ratio (dimensionless)effectiveness (dimensionless)ntu (dimensionless)
Shell-and-tube 2-pass0.25 0.50.250.380.5
Shell-and-tube 2-pass0.25 1.00.250.591
Shell-and-tube 2-pass0.25 1.50.250.731.5
Shell-and-tube 2-pass0.25 2.00.250.82
Shell-and-tube 2-pass0.25 2.50.250.862.5
Shell-and-tube 2-pass0.25 3.00.250.913
Shell-and-tube 2-pass0.25 4.00.250.954
Shell-and-tube 2-pass0.25 5.00.250.975
Shell-and-tube 2-pass0.50 0.00.500
Shell-and-tube 2-pass0.50 0.50.50.360.5

What else is in Engineering Database