Sample data from Engineering Database — 375 reference tables, deterministic calculators, and Engineering AI. Sign up free

Effectiveness Ntu: Crossflow Cmin mixed

1.00 1.5 to 1.00 5.0

Heat exchanger effectiveness (ε) vs. number of transfer units (NTU) and capacity ratio (Cr = Cmin/Cmax) for seven flow configurations: parallel-flow, counterflow, shell-and-tube 1-pass, shell-and-tube 2-pass, crossflow both unmixed, crossflow Cmin mixed, crossflow Cmax mixed. Data digitized from Incropera Figures 11.10-11.15.

Mechanical Engineeringhx configuration: Crossflow Cmin mixed6 rowsPage 4 of 4
hx configurationskcapacity ratio (dimensionless)effectiveness (dimensionless)mixed fluidntu (dimensionless)
Crossflow Cmin mixed1.00 1.510.62C min1.5
Crossflow Cmin mixed1.00 2.010.69C min2
Crossflow Cmin mixed1.00 2.510.75C min2.5
Crossflow Cmin mixed1.00 3.010.79C min3
Crossflow Cmin mixed1.00 4.010.85C min4
Crossflow Cmin mixed1.00 5.010.88C min5