Effectiveness Ntu: Crossflow Cmin mixed

0.50 0.5 to 0.75 0.5

Heat exchanger effectiveness (ε) vs. number of transfer units (NTU) and capacity ratio (Cr = Cmin/Cmax) for seven flow configurations: parallel-flow, counterflow, shell-and-tube 1-pass, shell-and-tube 2-pass, crossflow both unmixed, crossflow Cmin mixed, crossflow Cmax mixed. Data digitized from Incropera Figures 11.10-11.15.

Mechanical Engineeringhx configuration: Crossflow Cmin mixed10 rowsPage 2 of 4
hx configurationskcapacity ratio (dimensionless)effectiveness (dimensionless)mixed fluidntu (dimensionless)
Crossflow Cmin mixed0.50 0.50.50.36C min0.5
Crossflow Cmin mixed0.50 1.00.50.56C min1
Crossflow Cmin mixed0.50 1.50.50.69C min1.5
Crossflow Cmin mixed0.50 2.00.50.78C min2
Crossflow Cmin mixed0.50 2.50.50.83C min2.5
Crossflow Cmin mixed0.50 3.00.50.87C min3
Crossflow Cmin mixed0.50 4.00.50.92C min4
Crossflow Cmin mixed0.50 5.00.50.95C min5
Crossflow Cmin mixed0.75 0.00.750C min0
Crossflow Cmin mixed0.75 0.50.750.34C min0.5