Effectiveness Ntu: Crossflow Cmax mixed

0.75 1.0 to 1.00 1.0

Heat exchanger effectiveness (ε) vs. number of transfer units (NTU) and capacity ratio (Cr = Cmin/Cmax) for seven flow configurations: parallel-flow, counterflow, shell-and-tube 1-pass, shell-and-tube 2-pass, crossflow both unmixed, crossflow Cmin mixed, crossflow Cmax mixed. Data digitized from Incropera Figures 11.10-11.15.

Mechanical Engineeringhx configuration: Crossflow Cmax mixed10 rowsPage 3 of 4
hx configurationskcapacity ratio (dimensionless)effectiveness (dimensionless)mixed fluidntu (dimensionless)
Crossflow Cmax mixed0.75 1.00.750.48C max1
Crossflow Cmax mixed0.75 1.50.750.59C max1.5
Crossflow Cmax mixed0.75 2.00.750.67C max2
Crossflow Cmax mixed0.75 2.50.750.72C max2.5
Crossflow Cmax mixed0.75 3.00.750.76C max3
Crossflow Cmax mixed0.75 4.00.750.82C max4
Crossflow Cmax mixed0.75 5.00.750.86C max5
Crossflow Cmax mixed1.00 0.010C max0
Crossflow Cmax mixed1.00 0.510.33C max0.5
Crossflow Cmax mixed1.00 1.010.5C max1