Effectiveness Ntu: Crossflow Cmax mixed

0.50 0.5 to 0.75 0.5

Heat exchanger effectiveness (ε) vs. number of transfer units (NTU) and capacity ratio (Cr = Cmin/Cmax) for seven flow configurations: parallel-flow, counterflow, shell-and-tube 1-pass, shell-and-tube 2-pass, crossflow both unmixed, crossflow Cmin mixed, crossflow Cmax mixed. Data digitized from Incropera Figures 11.10-11.15.

Mechanical Engineeringhx configuration: Crossflow Cmax mixed10 rowsPage 2 of 4
hx configurationskcapacity ratio (dimensionless)effectiveness (dimensionless)mixed fluidntu (dimensionless)
Crossflow Cmax mixed0.50 0.50.50.3C max0.5
Crossflow Cmax mixed0.50 1.00.50.45C max1
Crossflow Cmax mixed0.50 1.50.50.55C max1.5
Crossflow Cmax mixed0.50 2.00.50.63C max2
Crossflow Cmax mixed0.50 2.50.50.68C max2.5
Crossflow Cmax mixed0.50 3.00.50.72C max3
Crossflow Cmax mixed0.50 4.00.50.78C max4
Crossflow Cmax mixed0.50 5.00.50.81C max5
Crossflow Cmax mixed0.75 0.00.750C max0
Crossflow Cmax mixed0.75 0.50.750.32C max0.5