Sample data from Engineering Database — 375 reference tables, deterministic calculators, and Engineering AI. Sign up free

Effectiveness Ntu: Counterflow

0.50 1.0 to 0.75 1.0

Heat exchanger effectiveness (ε) vs. number of transfer units (NTU) and capacity ratio (Cr = Cmin/Cmax) for seven flow configurations: parallel-flow, counterflow, shell-and-tube 1-pass, shell-and-tube 2-pass, crossflow both unmixed, crossflow Cmin mixed, crossflow Cmax mixed. Data digitized from Incropera Figures 11.10-11.15.

Mechanical Engineeringhx configuration: Counterflow10 rowsPage 3 of 5
hx configurationskcapacity ratio (dimensionless)effectiveness (dimensionless)ntu (dimensionless)
Counterflow0.50 1.00.50.561
Counterflow0.50 1.50.50.691.5
Counterflow0.50 2.00.50.772
Counterflow0.50 2.50.50.832.5
Counterflow0.50 3.00.50.883
Counterflow0.50 4.00.50.944
Counterflow0.50 5.00.50.975
Counterflow0.75 0.00.7500
Counterflow0.75 0.50.750.340.5
Counterflow0.75 1.00.750.521

What else is in Engineering Database

Related data