Effectiveness Ntu: Counterflow

0.25 0.5 to 0.50 0.5

Heat exchanger effectiveness (ε) vs. number of transfer units (NTU) and capacity ratio (Cr = Cmin/Cmax) for seven flow configurations: parallel-flow, counterflow, shell-and-tube 1-pass, shell-and-tube 2-pass, crossflow both unmixed, crossflow Cmin mixed, crossflow Cmax mixed. Data digitized from Incropera Figures 11.10-11.15.

Mechanical Engineeringhx configuration: Counterflow10 rowsPage 2 of 5
hx configurationskcapacity ratio (dimensionless)effectiveness (dimensionless)ntu (dimensionless)
Counterflow0.25 0.50.250.380.5
Counterflow0.25 1.00.250.61
Counterflow0.25 1.50.250.741.5
Counterflow0.25 2.00.250.822
Counterflow0.25 2.50.250.892.5
Counterflow0.25 3.00.250.933
Counterflow0.25 4.00.250.974
Counterflow0.25 5.00.250.995
Counterflow0.50 0.00.500
Counterflow0.50 0.50.50.360.5

What else is in Engineering Database