Control Actuation Forces: rocker_switch

MIL-STD-1472F control actuation force and displacement requirements — min/max resistance (N) and displacement (mm or degrees) for every control type by hand condition (bare/gloved/heavy handwear/foot). Covers pushbuttons, foot switches, keyboards, toggle switches, legend switches, rocker switches, levers, isotonic joysticks, pedals, mouse buttons, and handwheels per Section 5.4 Figures 12-21 and Tables IX, X, XII.

Aerospace Engineeringcontrol_type: rocker_switch2 rows
control typerecord idhand conditionnotesparameterunit imperialunit metricvalue min imperial (lb, oz, or in (see unit_imperial))value min metric (N or mm or deg (see unit_metric))
rocker_switchrocker_switch_bare_displacement_angleanyMinimum actuation angle (30 deg)displacement_angledegdeg3030
rocker_switchrocker_switch_bare_displacement_linearbare_handMinimum linear displacement when depresseddisplacementinmm0.1253

This is a sample. Search the full control actuation forces dataset and 300+ more by creating a free account and accessing the database.

Get started for FREE