Control Actuation Forces: legend_switch

MIL-STD-1472F control actuation force and displacement requirements — min/max resistance (N) and displacement (mm or degrees) for every control type by hand condition (bare/gloved/heavy handwear/foot). Covers pushbuttons, foot switches, keyboards, toggle switches, legend switches, rocker switches, levers, isotonic joysticks, pedals, mouse buttons, and handwheels per Section 5.4 Figures 12-21 and Tables IX, X, XII.

Aerospace Engineeringcontrol_type: legend_switch3 rows
control typerecord idhand conditionnotesparameterunit imperialunit metricvalue max imperial (lb, oz, or in (see unit_imperial))value max metric (N or mm or deg (see unit_metric))value min imperial (lb, oz, or in (see unit_imperial))value min metric (N or mm or deg (see unit_metric))
legend_switchlegend_switch_membrane_conductive_displacementbare_handConductive membrane displacementdisplacementinmm0.0410.041
legend_switchlegend_switch_membrane_conductive_resistancebare_handMembrane legend switch; conductive membrane contactresistanceozN11372
legend_switchlegend_switch_membrane_dome_displacementbare_handMembrane dome snap-action displacementdisplacementinmm0.250.030.7

This is a sample. Search the full control actuation forces dataset and 300+ more by creating a free account and accessing the database.

Get started for FREE