Concrete Admixtures: Type_G
Concrete chemical admixture reference data — ASTM C494 Types A/B/C/D/E/F/G/S, ASTM C260 air-entraining, calcium nitrite corrosion inhibitors, VMA, SRA, and lithium nitrate ASR mitigation. Parameters include dosage range (mL/100 kg cement), water reduction (%), initial/final set time change (min), compressive strength effect at 1/7/28 days (%), slump increase (mm), air content change (%), and compatibility notes.
| admixture type | product class | air content change pct (%) | astm standard | common name | compatibility notes | dosage max mL per 100kg (mL/100kg-cement) | dosage min mL per 100kg (mL/100kg-cement) | dosage typical mL per 100kg (mL/100kg-cement) | set time change final min (minutes) | set time change initial min (minutes) | slump increase mm (mm) | strength 1d pct change (%) | strength 28d pct change (%) | strength 7d pct change (%) | water reduction max pct (%) | water reduction min pct (%) | water reduction typical pct (%) |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Type_G | HRWR_retarder_naphthalene | 0 | ASTM C494 | HRWR + retarder (naphthalene-based) | Extended slump retention; for transit-mixed SCC; verify set time in warm weather | 1,950 | 390 | 780 | 90 | 60 | 130 | 5 | 15 | 15 | 20 | 10 | 15 |
| Type_G | HRWR_retarder_polycarboxylate | 0 | ASTM C494 | HRWR + retarder (PCE-based) | Extended workability for hot weather or long haul with high water reduction; common in ready-mix; test for compatibility | 1,950 | 260 | 650 | 90 | 60 | 150 | 10 | 20 | 20 | 30 | 12 | 18 |