Explore the Engineering Database more efficiently by signing up for free. Sign up free

Etd-300F-a-Mean — AS4 Pr 500

Material System
AS4 Pr 500
Condition Basis
Etd 300F a Mean
E1 GPa (GPa)
65.569
G12 GPa (GPa)
2.489
S MPa (MPa)
46.884
Xc MPa (MPa)
552.27
Xt MPa (MPa)
765.318
Basis
Mean
Category
Carbon Composite
Density Kg M3 (kg/m3)
1,570
Fiber
AS4
Matrix
Pr 500
Ply Thickness MM (mm)
0.3493
Source Page
257; 260; 262; 265
Source Table
Table 4.2.26(B); Table 4.2.26(E); Table 4.2.26(G); Table 4.2.26(J)
Test Condition
Etd (300F/A)