Explore the Engineering Database more efficiently by signing up for free. Sign up free
7001-Air-28.0-110-3-Ec-Maximum — Trimarc-1 Ti-6Al-2Sn-4Zr-2Mo Wire Fiber Wound Panel
- Material System
- Trimarc-1 Ti-6Al-2Sn-4Zr-2Mo Wire Fiber Wound Panel
- Condition Property Stat
- 7001 Air 28.0 1·10-3 Ec Maximum
- Condition
- 7001 | Air | 28.0 | 1·10-3
- Orientation Or Layup
- [0]
- Property
- Ec
- Source Page
- 244
- Source Verification Method
- Spot-Check vs Parsed Csv (aieng/tables/knowledge/cmh-VOL4-*) Or Vector Pdf Text (CMH Vol 4.PDF), 12 Rows per (material system, Table id) bucket, All 43 Buckets Matched at 100%
- Source Verified
- True
- Source Verified at
- 2026-05-05
- Statistic
- Maximum
- Table Id
- 3.8.2.2.2(C)
- Unit
- Msi
- Value
- 1
- Value Text
- 1