Home/Reference Data/Cmh17 Mmc Cmc Properties/TRIMARC-1_Ti-6Al-2Sn-4Zr-2Mo_wire_fiber_wound_panel

Cmh17 Mmc Cmc Properties: TRIMARC-1_Ti-6Al-2Sn-4Zr-2Mo_wire_fiber_wound_panel

CMH-17 Vol 4 Section 3 detailed statistical summary properties for metal matrix composites (MMC) and ceramic matrix composites (CMC). Includes fiber properties (Nextel 610, SCS-6), composite mechanical properties (Ftu, Fty, Fcy, Et, Ec, Poisson ratio, elongation) with full statistical data (mean, min, max, CV, B-value, distribution) across multiple temperatures and environments.

Aerospace Engineeringmaterial_system: TRIMARC-1_Ti-6Al-2Sn-4Zr-2Mo_wire_fiber_wound_panel3 rows
material systemcondition property statconditionorientation or layuppropertysource pagestatistictable idunitvaluevalue text
TRIMARC-1_Ti-6Al-2Sn-4Zr-2Mo_wire_fiber_wound_panel3251_Air_27.3_1·10-4_Ec_23251 | Air | 27.3 | 1·10-4[90]Ec24623.8.2.2.2(e)Msi11
TRIMARC-1_Ti-6Al-2Sn-4Zr-2Mo_wire_fiber_wound_panel3251_Air_27.3_1·10-4_Ec_Ec_C.V.%3251 | Air | 27.3 | 1·10-4[90]Ec246Ec C.V.(%)3.8.2.2.2(e)Msi22
TRIMARC-1_Ti-6Al-2Sn-4Zr-2Mo_wire_fiber_wound_panel3251_Air_27.3_1·10-4_Ec_Maximum3251 | Air | 27.3 | 1·10-4[90]Ec246Maximum3.8.2.2.2(e)Msi19.919.9