1500hp 50ft to 200hp 75ft

CHP (combined heat and power) system reference data from ASHRAE 2020 Ch.7 — CHP efficiency metrics, boiler heat recovery factors, grid electrical efficiency references, reciprocating engine sizing, exhaust pipe sizing, gas fuel line pressures, engine room ventilation, maintenance intervals, fuel cell technology comparison, theoretical steam rates, steam turbine governor classes, heat recovery temperature ranges, engine exhaust properties, and engine-driven chiller COP

Mechanical Engineeringparameter type: exhaust pipe diameter10 rowsPage 2 of 5
parameter typeparameter iddescriptionunitvalue text
exhaust pipe diameter1500hp 50ftMinimum exhaust pipe diameter — 1500 hp engine 50 ft equivalent pipe lengthin13
exhaust pipe diameter1500hp 75ftMinimum exhaust pipe diameter — 1500 hp engine 75 ft equivalent pipe lengthin15
exhaust pipe diameter2000hp 100ftMinimum exhaust pipe diameter — 2000 hp engine 100 ft equivalent pipe lengthin17
exhaust pipe diameter2000hp 25ftMinimum exhaust pipe diameter — 2000 hp engine 25 ft equivalent pipe lengthin15
exhaust pipe diameter2000hp 50ftMinimum exhaust pipe diameter — 2000 hp engine 50 ft equivalent pipe lengthin16
exhaust pipe diameter2000hp 75ftMinimum exhaust pipe diameter — 2000 hp engine 75 ft equivalent pipe lengthin17
exhaust pipe diameter200hp 100ftMinimum exhaust pipe diameter — 200 hp engine 100 ft equivalent pipe lengthin7
exhaust pipe diameter200hp 25ftMinimum exhaust pipe diameter — 200 hp engine 25 ft equivalent pipe lengthin6
exhaust pipe diameter200hp 50ftMinimum exhaust pipe diameter — 200 hp engine 50 ft equivalent pipe lengthin6
exhaust pipe diameter200hp 75ftMinimum exhaust pipe diameter — 200 hp engine 75 ft equivalent pipe lengthin7