2.0-A0.1-B0.1 — Life Test Parameters

Table Id
Life Test Parameters
Param Key
2.0 A0.1 B0.1
Alpha
0.1
Beta
0.1
Chi Sq Half 1MINUS Alpha 2R
10.3
Expected Failures at LAMBDA0
10.2
Expected Failures at LAMBDA1
14.8
Expected Failures Trunc at LAMBDA0
5.7
Expected Failures Trunc at LAMBDA1
9.1
Gamma
2
Rejection Number R
15
Standard
Amcp 706-198 Table 3-8
Truncation Number R
45

Source: AMCP 706-198 Table 3-8