Explore the Engineering Database more efficiently by signing up for free. Sign up free

1.5-A0.1-B0.25 — Life Test Parameters

Table Id
Life Test Parameters
Param Key
1.5 A0.1 B0.25
Alpha
0.1
Beta
0.25
Chi Sq Half 1MINUS Alpha 2R
18.84
Expected Failures at LAMBDA0
18.7
Expected Failures at LAMBDA1
24.2
Expected Failures Trunc at LAMBDA0
10.1
Expected Failures Trunc at LAMBDA1
16.5
Gamma
1.5
Rejection Number R
25
Standard
Amcp 706-198 Table 3-8
Truncation Number R
75

Source: AMCP 706-198 Table 3-8

life_test_parameters — param key 1.5_a0.1_b0.25 · expected failures trunc at lambda1 16.5 · expected failures trunc at lambda0 10.1 · expected failures at lambda1 24.2 · chi sq half 1minus alpha 2r 18.84 | Amcp Reliability Test Design | Engineering Database