Ti-6Al-6V-2Sn Bar Solution Treated and Aged vs Ti-6Al-6V-2Sn Sheet/Strip/Plate Annealed
Property comparison of Ti-6Al-6V-2Sn Bar Solution Treated and Aged and Ti-6Al-6V-2Sn Sheet/Strip/Plate Annealed, both titanium alloy.
| Property | Ti-6Al-6V-2Sn Bar Solution Treated and Aged | Ti-6Al-6V-2Sn Sheet/Strip/Plate Annealed | Difference |
|---|---|---|---|
| Yield strength | 1,103 MPa | 965.3 MPa | -13% |
| Tensile strength | 1,207 MPa | 1,034 MPa | -14% |
| Elongation | 8 % | 10 % | +25% |
| Elastic modulus | 110,316 MPa | 110,316 MPa | 0% |
| Shear modulus | 42,748 MPa | 42,748 MPa | 0% |
| Poisson ratio | 0.31 | 0.31 | 0% |
| Density | 4,540 kg/m³ | 4,540 kg/m³ | 0% |
Difference is Ti-6Al-6V-2Sn Sheet/Strip/Plate Annealed relative to Ti-6Al-6V-2Sn Bar Solution Treated and Aged. Values are taken from the representative row of each material; both materials may have multiple heat treatments or conditions on their individual pages.
Identification
- grade
- Ti-6Al-6V-2Sn
- standard
- MIL-HDBK-5J
- heat treatment
- Solution Treated and Aged
- grade
- Ti-6Al-6V-2Sn
- standard
- MIL-HDBK-5J
- heat treatment
- Annealed
What else is in Engineering Database
AI built for engineering. Searches the engineering database, performs calculations, gives source-backed engineering insights.
Get started for free ↗Reference Data375 engineering tablesMaterial properties, pipe and shape dimensions, code tables, and electrical ratings across mechanical, civil, chemical, electrical, materials, and manufacturing engineering.
Browse dataCalculatorsDeterministic engineering calculatorsSizing, checking, and conversion tools that run against the reference tables. Inputs are code-compliant, outputs are traceable to the source standard.