Part of Engineering Database. 375 reference tables, deterministic calculators, and Engineering AI. Sign up free
Home/Compare/Polymer/LCP (Liquid Crystal Polymer Vectra A950) vs Nylon 6 (PA6) Unfilled

LCP (Liquid Crystal Polymer Vectra A950) vs Nylon 6 (PA6) Unfilled

Property comparison of LCP (Liquid Crystal Polymer Vectra A950) and Nylon 6 (PA6) Unfilled, both polymer.

Polymer8 compared properties
PropertyLCP (Liquid Crystal Polymer Vectra A950)Nylon 6 (PA6) UnfilledDifference
Tensile strength148 MPa80 MPa-46%
Elongation3.4 %30 %+782%
Elastic modulus10,600 MPa3,000 MPa-72%
Poisson ratio0.40.40%
Density1,400 kg/m³1,130 kg/m³-19%
Thermal conductivity0.2 W/m·K0.25 W/m·K+25%
Specific heat1,100 J/kg·K1,700 J/kg·K+55%
Coefficient of thermal expansion-0.000004 1/K0.00008 1/K+2100%

Difference is Nylon 6 (PA6) Unfilled relative to LCP (Liquid Crystal Polymer Vectra A950). Values are taken from the representative row of each material; both materials may have multiple heat treatments or conditions on their individual pages.

Identification

LCP (Liquid Crystal Polymer Vectra A950)
standard
ASTM
Nylon 6 (PA6) Unfilled
standard
ASTM

What else is in Engineering Database

Related comparisons

View each material