Turbomachinery Maps: centrifugal_pump_60
Turbomachinery performance maps — compressor, turbine, fan, pump, and turbocharger characteristic curves showing efficiency, pressure ratio, head coefficient, and surge/choke boundaries at various speeds and flow rates
| machine speed | flow pct | flow coefficient | is choke point | is surge point | isentropic efficiency pct (%) | machine type | notes | speed pct (%) |
|---|---|---|---|---|---|---|---|---|
| centrifugal_pump_60 | 100 | 0.12 | false | false | 77 | centrifugal_pump | Design flow at 60% speed; head barely reaches system static head in many applications; minimum speed concern | 60 |
| centrifugal_pump_60 | 30 | 0.036 | false | false | 68 | centrifugal_pump | Very low flow pump 60% speed; low head (N^2 = 0.36); limited practical operating range | 60 |
| centrifugal_pump_60 | 40 | 0.048 | false | false | 73.5 | centrifugal_pump | Low flow pump 60% speed; efficiency rising; highly reduced head output vs full speed | 60 |
This is a sample. Search the full turbomachinery maps dataset and 300+ more by creating a free account and accessing the database.
Get started for FREERelated data
axial_compressor_603 rowsaxial_compressor_703 rowsaxial_compressor_803 rowsaxial_compressor_903 rowsaxial_compressor_1003 rowsaxial_turbine_703 rowsaxial_turbine_803 rowsaxial_turbine_903 rowsaxial_turbine_1003 rowscentrifugal_compressor_603 rowscentrifugal_compressor_703 rowscentrifugal_compressor_803 rows