Distillation and absorption tray column design parameters — sieve, valve, bubble cap, dual-flow, baffle, and chimney tray geometry, hydraulics, flood limits, and turndown ratios; plus system derating factors, downcomer hydraulics, downcomer residence times, typical theoretical stages by separation system, and Murphree tray efficiency ranges

Chemical Engineeringtray type: downcomer velocity low1 row
tray typecategorydowncomer cl velocity ft s max (ft/s)downcomer cl velocity ft s min (ft/s)foaming tendencysystem servicetray spacing in (in)
downcomer velocity lowdowncomer clear liquid velocity0.50.4lowLow-pressure (<100 psia) light hydrocarbons; stabilizers; air-water simulators18