Home/Reference Data/Structural Glass Properties

Structural Glass Properties

Mechanical, thermal, and optical properties for architectural and structural glass types. Covers annealed float (3-19 mm), heat-strengthened (4-15 mm), fully tempered (4-19 mm), laminated annealed and tempered (PVB and SGP interlayers), insulating glass units (double clear, double low-E, double high-performance, triple clear, triple low-E), chemically strengthened (2-3 mm), wired glass, and ceramic frit tempered glass. Each record includes density, elastic modulus, Poisson's ratio, characteristic strength, allowable stress (short and long duration), surface compressive stress range, thermal expansion coefficient, thermal conductivity, U-value (IGU), SHGC, visible transmittance, breakage pattern, and deflection limit. 43 records per EN 572/EN 16612, ASTM E1300, ASTM C1048, and NFRC standards.

Civil Engineering9 sections24 sample rowsKey: glass_type

Attributes

subtype
thickness_mmmm
configuration
density_kg_per_m3kg/m^3
modulus_of_elasticity_GPaGPa
poisson_ratiodimensionless
characteristic_strength_MPaMPa
allowable_stress_MPa_shortMPa
allowable_stress_MPa_longMPa
surface_compressive_stress_MPa_minMPa
surface_compressive_stress_MPa_maxMPa
thermal_expansion_coeff_per_C1/degC
thermal_conductivity_W_per_mKW/(m*K)
U_value_center_W_per_m2KW/(m^2*K)
SHGCdimensionless
visible_transmittancedimensionless
breakage_pattern
deflection_limit_L_overdimensionless
notes

Browse data

Search the full structural glass properties dataset with natural language or structured queries.

Search this table