Sample data from Engineering Database — 375 reference tables, deterministic calculators, and Engineering AI. Sign up free

Steam Superheated: 400

0.0#liquid to 1400.0#supercritical fluid

Superheated steam and compressed liquid tables — thermodynamic properties (enthalpy, entropy, specific volume, density) at various pressures and temperatures

Mechanical Engineeringpressure MPa: 40010 rowsPage 1 of 6
pressure MPasort keyh kJ kg (kJ/kg)phaserho kg m3 (kg/m3)s kJ kgK (kJ/kgK)temp C (C)u kJ kg (kJ/kg)v m3 kg (m3/kg)
4000.0#liquid343.44liquid1,138.7-0.103240-7.8360.000878
40010.0#liquid380.12liquid1,1340.028611027.3720.000882
400100.0#liquid722.72liquid1,087.91.0791100355.0480.000919
4001000.0#supercritical fluid4,112.6supercritical fluid532.85.72141,0003,361.840.001877
400110.0#liquid760.72liquid1,082.51.1796110391.1920.000924
400120.0#liquid798.7liquid1,076.91.2774120427.2680.000929
4001200.0#supercritical fluid4,803.7supercritical fluid460.016.22591,2003,934.140.002174
400130.0#liquid836.66liquid1,071.31.3728130463.2760.000933
400140.0#liquid874.61liquid1,065.61.4658140499.2260.000938
4001400.0#supercritical fluid5,469.3supercritical fluid406.386.64971,4004,485.020.002461