Spray Nozzle Data: misting

Spray nozzle performance data for fire protection, industrial cooling, gas scrubbing, dust suppression, and process applications. Covers full cone, hollow cone, flat fan, solid stream, misting, air atomizing, and NFPA 15 deluge nozzles. Key parameters: K-factor (Q=K*sqrt(P)), VMD/SMD droplet sizes, spray angle, flow rate, coverage area, material, and turndown ratio.

Civil Engineeringnozzle_type: misting3 rows
nozzle typespray angle flow keyK factor (gpm/psi^0.5)coverage diameter at 12in ft (ft)droplet size SMD microns (micron)droplet size VMD microns (micron)flow rate equationflow rate gpm (gpm)free passage diameter in (in)materialmax temperature F (degF)notesoperating pressure psi (psi)spray angle deg (deg)spray patternturndown ratio
misting120deg_0.25gpm_stainless_3160.020410.872120Q=K*sqrt(P)0.250.02stainless_316400Fog nozzle; 150 psi HP misting; sub-150 micron VMD; greenhouse/livestock cooling; outdoor cooling pads; K=0.25/12.247150120full_cone10:1
misting60deg_0.05gpm_stainless_3160.003540.360100Q=K*sqrt(P)0.050.008stainless_316400Ultra-fine mist; HP hydraulic atomization; 200 psi supply; VMD<150 microns; data center cooling fog; K=0.05/sqrt(200)=0.0035420060hollow_cone20:1
misting60deg_0.10gpm_stainless_3160.008160.490150Q=K*sqrt(P)0.10.01stainless_316400High-pressure misting nozzle; 100-200 psi operation; VMD <200 microns for evaporative cooling and humidification; K=Q/sqrt(P)=0.10/12.24715060full_cone10:1