assembly typeassembly idSTC rating (dimensionless)assembly descriptionconstruction detailfire rating hr (hr)frequency weaknessesthickness in (in)weight psf (lb/ft2)
partitionpartition_demountable_stc3232Demountable office partition STC 32Demountable gypsum panel partition; 3 in thick; mineral wool infill; acoustic seals; bottom track0Low-mass flanking at 125-250 Hz; STC 32-35 typical commercial grade; ceiling plenum flanking dominant35
partitionpartition_demountable_stc4242Demountable office partition STC 42High-performance demountable partition; 4.5 in; double-wall glass wool; perimeter seals; deck-to-deck0Deck-to-deck eliminates plenum flanking; STC 40-45 range for high-performance office4.58
partitionpartition_glass_1in40Full-height glass partition 1 in glazingFramed glass partition; 1 in laminated glass (PVB); floor-to-slab; sealed perimeter0Flanking via slab connection; coincidence at 500 Hz in glass; sealing critical for performance112