Sample data from Engineering Database — 375 reference tables, deterministic calculators, and Engineering AI. Sign up free

Refrigerants: R507A

23.603 to 36.557

Refrigerant saturation property tables — saturation pressures, temperatures, enthalpies, entropies, and specific volumes for 40 refrigerants (R134a, R410A, R404A, R22, R717/ammonia, R744/CO2, HFOs, natural refrigerants, cryogenics, etc.)

Mechanical Engineeringrefrigerant: R507A5 rowsPage 7 of 7
refrigerantpressure barhf kJ kg (kJ/kg)hfg kJ kg (kJ/kg)hg kJ kg (kJ/kg)sf kJ kgK (kJ/kgK)sfg kJ kgK (kJ/kgK)sg kJ kgK (kJ/kgK)temp C (C)temp F (F)vf m3 kg (m3/kg)vg m3 kg (m3/kg)
R507A23.603277.4199.11376.521.25360.30671.5603501220.0011140.00683
R507A26.409286.9188.63375.541.28180.27011.5519551310.0011680.00578
R507A29.476297.2875.98373.261.3120.22811.5401601400.0012410.0048
R507A32.838309.359.14368.441.34650.1751.5215651490.0013530.00384
R507A36.557328.3225.15353.471.40070.07331.474701580.0016680.0026

What else is in Engineering Database

Related data