Reactor Coolant Properties: liquid_sodium_SFR
Thermophysical properties of nuclear reactor coolants at operating temperatures and pressures. Covers light water (H2O) for PWR at 15.5 MPa (270-340°C) and BWR at 7 MPa (270-280°C), heavy water D2O for CANDU at 10 MPa (250-310°C), helium gas for HTGR/VHTR at 7 MPa (250-750°C), liquid sodium for SFR/LMFBR at near-atmospheric pressure (200-550°C), and molten salt FLiBe (2LiF-BeF2) for MSR (500-700°C). Properties: density, dynamic viscosity, thermal conductivity, specific heat, Prandtl number. Distinct from standard steam tables which do not cover D2O, sodium, helium, or FLiBe at reactor conditions.
| coolant type | temperature C | density kg m3 (kg/m3) | dynamic viscosity uPa s (uPa*s) | notes | prandtl number (dimensionless) | pressure MPa (MPa) | reactor type | specific heat J kgK (J/kgK) | thermal conductivity W mK (W/mK) |
|---|---|---|---|---|---|---|---|---|---|
| liquid_sodium_SFR | 200 | 919 | 700 | Liquid sodium near pump suction temperature SFR; atmospheric approx | 11 | 0.1 | SFR | 1,349 | 85.8 |
| liquid_sodium_SFR | 300 | 874 | 420 | Primary sodium circuit midrange; 300°C typical inlet | 6.9 | 0.1 | SFR | 1,290 | 78.2 |
| liquid_sodium_SFR | 350 | 851 | 330 | Core inlet to mid-core SFR | 5.6 | 0.1 | SFR | 1,272 | 74.5 |