| location id | record id | ari year (yr) | city | depth in (in) | depth mm (mm) | duration label | duration minutes (min) | latitude (deg) | longitude (deg) | state |
|---|---|---|---|---|---|---|---|---|---|---|
| austin tx | 5-min 1000yr | 1,000 | Austin | 1.88 | 47.752 | 5-min | 5 | 30.2672 | -97.7431 | TX |
| austin tx | 5-min 100yr | 100 | Austin | 1.28 | 32.512 | 5-min | 5 | 30.2672 | -97.7431 | TX |
| austin tx | 5-min 10yr | 10 | Austin | 0.798 | 20.2692 | 5-min | 5 | 30.2672 | -97.7431 | TX |
| austin tx | 5-min 1yr | 1 | Austin | 0.431 | 10.9474 | 5-min | 5 | 30.2672 | -97.7431 | TX |
| austin tx | 5-min 200yr | 200 | Austin | 1.45 | 36.83 | 5-min | 5 | 30.2672 | -97.7431 | TX |
| austin tx | 5-min 25yr | 25 | Austin | 0.979 | 24.8666 | 5-min | 5 | 30.2672 | -97.7431 | TX |
| austin tx | 5-min 2yr | 2 | Austin | 0.525 | 13.335 | 5-min | 5 | 30.2672 | -97.7431 | TX |
| austin tx | 5-min 500yr | 500 | Austin | 1.69 | 42.926 | 5-min | 5 | 30.2672 | -97.7431 | TX |
| austin tx | 5-min 50yr | 50 | Austin | 1.12 | 28.448 | 5-min | 5 | 30.2672 | -97.7431 | TX |
| austin tx | 5-min 5yr | 5 | Austin | 0.671 | 17.0434 | 5-min | 5 | 30.2672 | -97.7431 | TX |
What else is in Engineering Database
Iron Engine ↗Engineering AI at ironengine.ai
AI built for engineering. Searches the engineering database, performs calculations, gives source-backed engineering insights.
Get started for free ↗Reference Data375 engineering tablesMaterial properties, pipe and shape dimensions, code tables, and electrical ratings across mechanical, civil, chemical, electrical, materials, and manufacturing engineering.
Browse dataCalculatorsDeterministic engineering calculatorsSizing, checking, and conversion tools that run against the reference tables. Inputs are code-compliant, outputs are traceable to the source standard.
Browse calculators