pump typeflow gpmdescriptionefficiency pct (%)head ft (ft)hp rangeimpeller typenotesspecific speed ns (dimensionless)
centrifugal_vertical_turbine50Vertical turbine pump (well, intake, booster)471501-3francisOverall efficiency includes column and bearing losses (bowl efficiency is 3-5% higher).2,000
centrifugal_vertical_turbine100Vertical turbine pump (well, intake, booster)572003-7.5francisMulti-stage for deep well applications. Head shown is total system head.2,400
centrifugal_vertical_turbine200Vertical turbine pump (well, intake, booster)652505-15francisTypical municipal/irrigation well pump.2,800