Post Installed Anchor Design: undercut

Post-installed concrete anchor design capacities per ACI 318-19 Chapter 17: wedge expansion, sleeve expansion, screw (Tapcon-type), adhesive threaded rod, and undercut anchors; tension and shear LRFD design strengths for 3/8 to 1 inch diameters in 3000-6000 psi concrete, cracked and uncracked conditions

Civil Engineeringanchor_type: undercut3 rows
anchor typeanchor idconditiondiameter in (in)effective embedment hef in (in)embedment depth in (in)fc psi (psi)min edge distance in (in)min spacing in (in)phi shear (dimensionless)phi tension (dimensionless)shear capacity lb (lb)shear capacity typetension capacity lb (lb)tension capacity type
undercut0.5in#3in#3000psi#crackedcracked0.52.87533,0002.550.650.751,870steel2,020concrete_breakout
undercut0.5in#3in#4000psi#crackedcracked0.52.87534,0002.550.650.751,870steel2,334concrete_breakout
undercut0.5in#3in#4000psi#uncrackeduncracked0.52.87534,0002.550.650.751,870steel3,090concrete_breakout