Pipe fittings loss coefficients — Darby 3K method K-factors for elbows, tees, valves, and other fittings

Civil Engineeringfitting type: Valve, Plug valve, three-way (flow through)1 row
fitting typeK1 (dimensionless)K ref (dimensionless)Kd (dimensionless)Ki (dimensionless)categorydescription
Valve, Plug valve, three-way (flow through)3000.59786140.14ValveDarby 3K: K = 300.0/Re + 0.14*(1 + 4.0/D^0.3)