Sample data from Engineering Database — 375 reference tables, deterministic calculators, and Engineering AI. Sign up free
Home/Reference Data/Pipe Fittings/Tee, Run-through, stub-in branch

Pipe Fittings: Tee, Run-through, stub-in branch

Pipe fittings loss coefficients — Darby 3K method K-factors for elbows, tees, valves, and other fittings

Civil Engineeringfitting type: Tee, Run-through, stub-in branch1 row
fitting typeK1 (dimensionless)K ref (dimensionless)Kd (dimensionless)Ki (dimensionless)categorydescription
Tee, Run-through, stub-in branch1000.00100TeeDarby 3K: K = 100.0/Re + 0.0*(1 + 0.0/D^0.3)

What else is in Engineering Database

Calculators that use this data

Related data