Civil Engineeringpile type: 16IN PRECAST SQUARE1 row
pile typearea in2 (in2)depth in (in)end bearing clay ksf max (ksf)end bearing clay ksf min (ksf)end bearing sand ksf max (ksf)end bearing sand ksf min (ksf)min embedment ft (ft)perimeter in (in)skin friction clay ksf max (ksf)skin friction clay ksf min (ksf)skin friction sand ksf max (ksf)skin friction sand ksf min (ksf)standardstructural capacity kips A36 (kips)structural capacity kips A572 (kips)weight plf (lb/ft)width in (in)
16IN PRECAST SQUARE256162881806015641.40.520.7PCI Design Handbook 8th Ed; AASHTO LRFD 9th Ed Section 5.14.41,1521,15226716

What else is in Engineering Database

Calculators that use this data

Related data