Nuclear Shielding Attenuation: concrete ordinary
Mass attenuation coefficients, linear attenuation coefficients, half-value layers (HVL), tenth-value layers (TVL), and buildup factors for gamma-ray and neutron shielding design. Covers lead, ordinary concrete, barite concrete, steel, water, polyethylene, borated polyethylene, and tungsten at gamma energies from 0.1 to 10 MeV. Neutron removal cross sections for fast and thermal neutrons. Sources: NIST XCOM database, ANSI/ANS-6.4.3-1991 buildup factors.
| shielding material | radiation energy key | density g per cm3 (g/cm3) | energy MeV (MeV) | radiation type | standard |
|---|---|---|---|---|---|
| concrete ordinary | neutron thermal#0.0253 | 2.3 | 0.0253 | neutron thermal | Thermal neutron macro removal in ordinary concrete; low hydrogen content limits moderation efficiency |