speciesgradeE psi (psi)Emin psi (psi)Fb psi (psi)Fc perp psi (psi)Fc psi (psi)Ft psi (psi)Fv psi (psi)Ggrading rules agencysize classificationstandardtable id
HEM-FIRSelect Structural|Beams and Stringers|4D1,300,000470,0001,3004059257501400.43WCLIB, WWPABeams and StringersNDS-2018 Supplement4D
HEM-FIRSelect Structural|Posts and Timbers|4D1,300,000470,0001,2004059758001400.43WCLIB, WWPAPosts and TimbersNDS-2018 Supplement4D
HEM-FIRStandard1,200,000440,0005504051,3003251500.43WCLIB, WWPA2" - 4" wideNDS-2018 Supplement4A
HEM-FIRStud1,200,000440,0006754058004001500.43WCLIB, WWPA2" & widerNDS-2018 Supplement4A
HEM-FIRUtility1,100,000400,0002504058501501500.43WCLIB, WWPA2" - 4" wideNDS-2018 Supplement4A