Sample data from Engineering Database — 375 reference tables, deterministic calculators, and Engineering AI. Sign up free

Nds Timber Design Values: HEM-FIR (NORTH)

Select Structural|Beams and Stringers|4D to Utility

NDS (National Design Specification) reference design values for visually graded dimension lumber — bending, tension, shear, compression, and modulus of elasticity

Civil Engineeringspecies: HEM-FIR (NORTH)5 rowsPage 2 of 2
speciesgradeE psi (psi)Emin psi (psi)Fb psi (psi)Fc perp psi (psi)Fc psi (psi)Ft psi (psi)Fv psi (psi)Ggrading rules agencysize classificationstandardtable id
HEM-FIR (NORTH)Select Structural|Beams and Stringers|4D1,300,000470,0001,2504059007251350.46NLGABeams and StringersNDS-2018 Supplement4D
HEM-FIR (NORTH)Select Structural|Posts and Timbers|4D1,300,000470,0001,1504059507751350.46NLGAPosts and TimbersNDS-2018 Supplement4D
HEM-FIR (NORTH)Standard1,400,000510,0006504051,5003501450.46NLGA2" - 4" wideNDS-2018 Supplement4A
HEM-FIR (NORTH)Stud1,400,000510,0007754059254501450.46NLGA2" & widerNDS-2018 Supplement4A
HEM-FIR (NORTH)Utility1,300,000470,0003004059751751450.46NLGA2" - 4" wideNDS-2018 Supplement4A