speciesgradeE psi (psi)Emin psi (psi)Fb psi (psi)Fc perp psi (psi)Fc psi (psi)Ft psi (psi)Fv psi (psi)Ggrading rules agencysize classificationstandardtable id
DOUGLAS FIR-SOUTHSelect Structural|Beams and Stringers|4D1,200,000440,0001,5505201,0009001650.46WWPABeams and StringersNDS-2018 Supplement4D
DOUGLAS FIR-SOUTHSelect Structural|Posts and Timbers|4D1,200,000440,0001,4505201,0509501650.46WWPAPosts and TimbersNDS-2018 Supplement4D
DOUGLAS FIR-SOUTHStandard1,100,000400,0005505201,4003501800.46WWPA2" - 4" wideNDS-2018 Supplement4A
DOUGLAS FIR-SOUTHStud1,100,000400,0006755208504251800.46WWPA2" & widerNDS-2018 Supplement4A
DOUGLAS FIR-SOUTHUtility1,000,000370,0002505209001501800.46WWPA2" - 4" wideNDS-2018 Supplement4A