Membrane Filtration: MF

Pressure-driven membrane filtration design parameters for MF, UF, NF, and RO systems — flux, TMP, pore size, MWCO, recovery, contaminant rejection (turbidity, bacteria, virus, TDS, NaCl, hardness, organics), fouling potential, cleaning frequency, and module configurations. Covers drinking water, wastewater reuse, leachate, and industrial applications.

Environmental Engineeringmembrane_type: MF2 rows
membrane typerecord idbacteria log removal maxbacteria log removal mincleaning frequencyflux lmh max (L/m2/h)flux lmh min (L/m2/h)flux lmh typical (L/m2/h)fouling potentialmaterialmodule configurationmwco daltons min (Da)notesparameter groupparameter namepore size um max (um)pore size um min (um)process categoryrecovery pct max (%)recovery pct min (%)tmp bar max (bar)tmp bar min (bar)turbidity rejection pctvirus log removal maxvirus log removal min
MFMF_CA_FS_DW43monthly803050lowcellulose_acetateflat_sheet500,000Susceptible to chlorine and pH extremes (pH 4-8); limited temperature range (max 35C); biodegradable membraneoperating_parametersMicrofiltration cellulose acetate flat sheet drinking water0.80.1drinking_water90800.30.0599.910
MFMF_CERAMIC_ALPHA54monthly400100200lowceramic_alpha_aluminatubular500,000Tolerates high temp (200C) and pH 0-14; long lifespan >10 yr; high capital cost; steam sterilizable; backflush with airoperating_parametersMicrofiltration ceramic alpha alumina drinking water1.40.1drinking_water98853.50.599.9910