Setting-Hysteresis — Torque Wrench
- Measurement Type
- Torque Wrench
- Uncertainty Source
- Setting Hysteresis
- Confidence Level Pct (%)
- 95
- Coverage Factor K
- 2
- Distribution
- Rectangular
- Divisor
- 1.732
- Expanded Uncertainty K2
- 3
- Expanded Uncertainty Unit
- Pct Rdg
- Standard
- ISO 6789-2:2017 Section 5.4
- Standard Uncertainty Unit
- Pct Rdg
- Standard Uncertainty Value
- 1.5
- Uncertainty Type
- Type B
Source: ISO 6789-2:2017 Section 5.4