Explore the Engineering Database more efficiently by signing up for free. Sign up free
Fluid-Density — Pressure Manometer Liquid
- Measurement Type
- Pressure Manometer Liquid
- Uncertainty Source
- Fluid Density
- Confidence Level Pct (%)
- 95
- Coverage Factor K
- 2
- Distribution
- Normal
- Divisor
- 2
- Expanded Uncertainty K2
- 0.04
- Expanded Uncertainty Unit
- Pct Fs
- Standard
- Perry's Chemical Engineers Handbook; ISO 5167
- Standard Uncertainty Unit
- Pct Fs
- Standard Uncertainty Value
- 0.02
- Uncertainty Type
- Type B
Source: Perry's Chemical Engineers Handbook; ISO 5167