Explore the Engineering Database more efficiently by signing up for free. Sign up free

Fluid-Density — Pressure Manometer Liquid

Measurement Type
Pressure Manometer Liquid
Uncertainty Source
Fluid Density
Confidence Level Pct (%)
95
Coverage Factor K
2
Distribution
Normal
Divisor
2
Expanded Uncertainty K2
0.04
Expanded Uncertainty Unit
Pct Fs
Standard
Perry's Chemical Engineers Handbook; ISO 5167
Standard Uncertainty Unit
Pct Fs
Standard Uncertainty Value
0.02
Uncertainty Type
Type B

Source: Perry's Chemical Engineers Handbook; ISO 5167

pressure_manometer_liquid — uncertainty source fluid_density · expanded uncertainty k2 0.04 · standard uncertainty value 0.02 · standard Perry's Chemical Engineers Handbook; ISO 5167 · uncertainty type Type_B | Measurement Uncertainty | Engineering Database