Masonry Design Values: CMU
w4 hollow N fm1350 to w8 hollow N fm1350
Masonry design values for CMU (concrete masonry units) and clay brick per TMS 402/602-22 (formerly ACI 530). Includes specified compressive strength f'm, modulus of elasticity Em, allowable stresses, dimensions, and grout strength for hollow and solid-grouted conditions with mortar types M, S, N, O.
| unit type | record id | actual height in (in) | actual length in (in) | actual width in (in) | allowable axial stress psi (psi) | allowable flexural tension psi (psi) | allowable shear vm psi (psi) | condition | f m psi (psi) | gross area in2 (in2) | grout strength psi (psi) | modular ratio n (dimensionless) | modulus of elasticity psi (psi) | mortar type | net area in2 (in2) | nominal width in (in) | standard | weight psf (psf) |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| CMU | w4 hollow N fm1350 | 7.625 | 15.625 | 3.625 | 203 | 18 | 33 | hollow | 1,350 | 56.9 | — | 24 | 1,215,000 | N | 19.5 | 4 | TMS 402/602-22 Table 2; NCMA TEK 18-01D; ASTM C90 | 20 |
| CMU | w6 grouted M or S fm1500 | 7.625 | 15.625 | 5.625 | 225 | 28 | 38 | grouted | 1,500 | 87.9 | 2,000 | 19 | 1,500,000 | M or S | 87.9 | 6 | TMS 402/602-22; NCMA TEK 17-01A | 50 |
| CMU | w6 hollow M or S fm1500 | 7.625 | 15.625 | 5.625 | 225 | 28 | 38 | hollow | 1,500 | 87.9 | — | 19 | 1,500,000 | M or S | 33.6 | 6 | TMS 402/602-22 Table 2; NCMA TEK 18-01D; ASTM C90 | 26 |
| CMU | w6 hollow N fm1350 | 7.625 | 15.625 | 5.625 | 203 | 18 | 33 | hollow | 1,350 | 87.9 | — | 24 | 1,215,000 | N | 33.6 | 6 | TMS 402/602-22 Table 2; NCMA TEK 18-01D | 26 |
| CMU | w8 grouted M or S fm1500 | 7.625 | 15.625 | 7.625 | 225 | 28 | 38 | grouted | 1,500 | 119.4 | 2,000 | 19 | 1,500,000 | M or S | 119.4 | 8 | TMS 402/602-22; NCMA TEK 17-01A; ASTM C476 | 56 |
| CMU | w8 grouted M or S fm2000 | 7.625 | 15.625 | 7.625 | 300 | 28 | 45 | grouted | 2,000 | 119.4 | 3,000 | 16 | 1,800,000 | M or S | 119.4 | 8 | TMS 402/602-22; NCMA TEK 17-01A | 56 |
| CMU | w8 hollow M or S fm1500 | 7.625 | 15.625 | 7.625 | 225 | 28 | 38 | hollow | 1,500 | 119.4 | — | 19 | 1,500,000 | M or S | 44.9 | 8 | TMS 402/602-22 Table 2; NCMA TEK 18-01D; ASTM C90 | 31 |
| CMU | w8 hollow M or S fm2000 | 7.625 | 15.625 | 7.625 | 300 | 28 | 45 | hollow | 2,000 | 119.4 | — | 16 | 1,800,000 | M or S | 44.9 | 8 | TMS 402/602-22 Table 2; NCMA TEK 18-01D | 31 |
| CMU | w8 hollow M or S fm2500 | 7.625 | 15.625 | 7.625 | 375 | 28 | 50 | hollow | 2,500 | 119.4 | — | 13 | 2,250,000 | M or S | 44.9 | 8 | TMS 402/602-22 Table 2; NCMA TEK 18-01D | 31 |
| CMU | w8 hollow N fm1350 | 7.625 | 15.625 | 7.625 | 203 | 18 | 33 | hollow | 1,350 | 119.4 | — | 24 | 1,215,000 | N | 44.9 | 8 | TMS 402/602-22 Table 2; NCMA TEK 18-01D | 31 |