Sample data from Engineering Database — 375 reference tables, deterministic calculators, and Engineering AI. Sign up free

Lmtd Correction Factors: both mixed

802 to 3002

LMTD correction factors (F) for heat exchangers — shell-and-tube (1-2, 1-4, 1-6, 2-4, 2-8) and crossflow arrangements at various R and P values

Mechanical Engineeringflow arrangement: both mixed10 rowsPage 2 of 3
flow arrangementR P keyF factorP valueR valuehx type
both mixed8020.58520.20.8crossflow
both mixed8030.98640.30.8crossflow
both mixed1,0010.27090.11crossflow
both mixed1,0020.60950.21crossflow
both mixed1,5010.28980.11.5crossflow
both mixed1,5020.6770.21.5crossflow
both mixed2,0010.30980.12crossflow
both mixed2,0020.75660.22crossflow
both mixed3,0010.35360.13crossflow
both mixed3,0020.97530.23crossflow