Lmtd Correction Factors: 2-4

1007 to 2004

LMTD correction factors (F) for heat exchangers — shell-and-tube (1-2, 1-4, 1-6, 2-4, 2-8) and crossflow arrangements at various R and P values

Mechanical Engineeringflow arrangement: 2-410 rowsPage 5 of 6
flow arrangementR P keyF factorP valueR valuehx typeshell passestube passes
2-41,0070.7010.71shell and tube24
2-41,5010.99920.11.5shell and tube24
2-41,5020.99550.21.5shell and tube24
2-41,5030.98530.31.5shell and tube24
2-41,5040.95740.41.5shell and tube24
2-41,5050.86450.51.5shell and tube24
2-42,0010.99880.12shell and tube24
2-42,0020.99310.22shell and tube24
2-42,0030.97320.32shell and tube24
2-42,0040.88770.42shell and tube24