Flow coefficients and performance data for hydraulic and pneumatic directional, pressure, and flow control valves — NFPA D03 through D10 body sizes and pneumatic 1/8" to 1" NPT port sizes. Covers Cv, Kv, nominal flow, pressure drop, leakage, response time, hysteresis, and frequency response.

Mechanical Engineeringvalve_type: counterbalance2 rows
valve typesize flow keyCv flow coefficient (gpm/psi^0.5)Kv metric (m3/hr/bar^0.5)leakage rate cc per min (cc/min)max pressure psi (psi)nominal flow gpm (gpm)notesoperating fluidpressure drop at rated flow psi (psi)size designation
counterbalanceNFPA_D03_10gpm_dP2002.82.455,00010Direct-acting counterbalance; set 125% of max load pressure; pilot ratio 3:1; internal leak at sethydraulic_oil,water_glycol,phosphate_ester200NFPA_D03
counterbalanceNFPA_D05_25gpm_dP2005.64.8105,00025Pilot-operated counterbalance; set 10-4500 psi; pilot ratio 4.5:1; Cv measured at 200 psi dPhydraulic_oil,water_glycol,phosphate_ester200NFPA_D05