Sample data from Engineering Database — 375 reference tables, deterministic calculators, and Engineering AI. Sign up free

Forced Convection Correlations: tube bank c2

staggered NL 10 to staggered NL 7

Nusselt number correlation constants for forced convection heat transfer. Covers external cross-flow over cylinders (Hilpert circular, noncircular shapes, Zukauskas), tube bank arrays (C1/m constants and C2 row correction factors), and fully developed laminar internal flow in noncircular ducts. Each record provides C and m coefficients for power-law Nu correlations, valid Reynolds number range, and source reference. 51 records from Incropera Chapter 7 (Tables 7.2-7.6) and Chapter 8 (Table 8.1).

Mechanical Engineeringcorrelation type: tube bank c28 rowsPage 2 of 2
correlation typecorrelation subtypeC (dimensionless)N L (dimensionless)Nu correlation textconditionsgeometry description
tube bank c2staggered NL 100.9710C2 correction factor: Nu NL = C2 * Nu (NL>=20)N L=10 rows deep; multiply Nu from Table 7.5 by C2Tube bank staggered N L=10 row correction
tube bank c2staggered NL 130.9813C2 correction factor: Nu NL = C2 * Nu (NL>=20)N L=13 rows deep; multiply Nu from Table 7.5 by C2Tube bank staggered N L=13 row correction
tube bank c2staggered NL 160.9916C2 correction factor: Nu NL = C2 * Nu (NL>=20)N L=16 rows deep; multiply Nu from Table 7.5 by C2Tube bank staggered N L=16 row correction
tube bank c2staggered NL 20.762C2 correction factor: Nu NL = C2 * Nu (NL>=20)N L=2 rows deep; multiply Nu from Table 7.5 by C2Tube bank staggered N L=2 row correction
tube bank c2staggered NL 30.843C2 correction factor: Nu NL = C2 * Nu (NL>=20)N L=3 rows deep; multiply Nu from Table 7.5 by C2Tube bank staggered N L=3 row correction
tube bank c2staggered NL 40.894C2 correction factor: Nu NL = C2 * Nu (NL>=20)N L=4 rows deep; multiply Nu from Table 7.5 by C2Tube bank staggered N L=4 row correction
tube bank c2staggered NL 50.925C2 correction factor: Nu NL = C2 * Nu (NL>=20)N L=5 rows deep; multiply Nu from Table 7.5 by C2Tube bank staggered N L=5 row correction
tube bank c2staggered NL 70.957C2 correction factor: Nu NL = C2 * Nu (NL>=20)N L=7 rows deep; multiply Nu from Table 7.5 by C2Tube bank staggered N L=7 row correction