Flowmeter Selection: velocity

Flowmeter selection guide covering 16 meter types across 6 categories (differential_pressure, velocity, mass_flow, electromagnetic, positive_displacement, variable_area, open_channel) — each record documents accuracy (% reading or full-scale), rangeability, pressure drop class, fluid compatibility, installation straight-run requirements, and relative cost class

Electrical Engineeringmeter_category: velocity3 rows
meter categorymeter typeaccuracy basisaccuracy pct reading (%)cost classcost relativedownstream diameters maxdownstream diameters min (pipe_diameters)fluid compatibilityfluid phasefluid restrictionsinstallation notesmeasurement principlemoving partsnotespressure drop classpressure drop notesrangeabilityrangeability numrequires powertemp limit C max (degC)temp limit C min (degC)typical applicationstypical pipe size in max (in)typical pipe size in min (in)upstream diameters max (pipe_diameters)upstream diameters min (pipe_diameters)
velocityturbine_inlinepercent_of_reading0.25medium255Clean viscous liquids and gases; petroleum productsliquid|gasRequires clean fluid; no slurries; minimum viscosity less than 10 cP for gas versionFlanged body; upstream strainer recommended; calibrated in-situRotor spins proportional to flow velocityyesHigh accuracy; AGA-7 approved for natural gas; OIML R 117; bearing wear limits lifemedium1 to 3 pct of line pressure loss20:120yes200-200Custody transfer petroleum, clean water, cryogenic LNG/LOX, process gas240.52010
velocityultrasonic_dopplerpercent_of_full_scale3low155Dirty liquids, slurries, wastewater - requires more than 100 ppm reflectorsliquidCannot measure clean liquids or gases; accuracy degrades with variable particle loadingClamp-on external transducers; no wetted partsFrequency shift of reflected ultrasonic signal from particles or bubblesnoLower accuracy than transit-time; best for relative measurement or flow verification; ISO 17089noneZero permanent pressure loss (clamp-on)20:120yes60-20Municipal wastewater, slurries, sludge, dredging12022010
velocityultrasonic_transit_timepercent_of_reading1medium3105Clean liquids and gases; some clamp-on for any pipeliquid|gasRequires acoustically homogeneous fluid; entrained air or bubbles cause error2-path or 4-path spool; clamp-on external transducers availableTime-of-flight difference between upstream and downstream ultrasonic pulsesnoAGA-9 (gas) / AGA-7 approved; clamp-on versions plus or minus 1 to 2 pct; multi-path 0.1 pct achievable; zero pressure dropnoneZero permanent pressure loss (clamp-on) or less than 0.1 pct (wetted spool)40:140yes200-200Custody transfer gas or liquid, clamp-on retrofit, water utilities, LNG12013010