Floor Vibration Criteria: frequency_limit
Acceptable floor vibration levels by occupancy and floor system: acceleration limits (%g), minimum natural frequencies (Hz), damping ratios, and effective weight factors. Sources: AISC Design Guide 11 2nd Ed., SCI P354, ISO 10137:2007
| criterion type | occupancy floor key | effective weight factor (dimensionless) | floor system | min natural frequency Hz (Hz) | occupancy type | source standard |
|---|---|---|---|---|---|---|
| frequency_limit | gymnasium#general#AISC_DG11 | 0.35 | general | 9 | gymnasium | AISC_DG11 |
| frequency_limit | office#PT_slab#AISC_DG11 | 0.4 | PT_slab | 4 | office | AISC_DG11 |
| frequency_limit | office#concrete_waffle#AISC_DG11 | 0.4 | concrete_waffle | 4 | office | AISC_DG11 |