Explore the Engineering Database more efficiently by signing up for free. Sign up free
0.8 — straight#rectangular
- Pk
- straight#rectangular
- mL Value
- 0.8
- L Definition
- Fin length; Use Corrected Lc=L+t/2 for Convective Tip
- Efficiency Eta
- 0.83
- Fin Profile
- Rectangular
- Fin Type
- Straight
- Formula
- tanh(mL)/mL
- Geometry Description
- Straight Fin Uniform Rectangular Cross-Section
- M Definition
- sqrt(hP/(k*Ac)) = SQRT(2H/(K*T)) for Flat Fin of Half-Thickness T
- Tip Condition
- Insulated